DISCONTINUED

REFLOW SIMULATOR AND WARPAGE MEASUREMENT SYSTEM(SRS-2)

Usage

Observe and measure the curving and warping of electronic parts and boards due to thermal stress, using actual reflow conditions.

Feature

  • ●Measure the warping of a part or board due to heat.
  • ●A laser on the underside measures the displacement in both X and Y-axis directions.
  • ●Dedicated software analyzes the displacement measurement data.

product specification

Item Specification
Model Name SRS-2
Applicable Circuit Board Up to 70W x 70L x 10H mm
Outer Dimension 652(W)×411(D)×425(H)(mm)
Heating Method Upper-face : Extreme infrared radiation with hot air
Lower-face : Extreme infrared radiation
Cooling Method Flowing air or N2 air (with flow adjustable valve)
Power Supply 200V 50/60Hz 1.6kVA 3Phase
Air 0.3 - 0.5MPa 100 liter/min (Maximum)
O2 Concentration in Furnace (when using N2) 100ppm minimum
PCB Installation Flat plate system (heat resistant glass or ceramic coated plate)
Upper-Heater Hot air heater : Approx. 675W (Approx.75W x 3 x 2lines+Approx.225W x 1) * Deviation to the standard nozzle can be set. Extreme infrared radiation heater : Approx. 360W
Lower-Heater Extreme infrared radiation heater : Approx. 360W
Temp. Accuracy 5C maximum (Maximum range : 50(W) x 50(L)mm in the center)
Measuring Temp. Range Room temp. - 330C
Measuring Points 3points
N2 Gas Supply Function 100 liter/min. with flow regulating valve during operation.
Weight Approx. 50kg

【Main Functions Secifications】

Item Specification
Displacement A laser displacement measuring sensor reads warpage from below the sample.
Measuring Range X and Y-axis : Max 70mm
Z : Reference point 0 - 3mm
Resolution (Warpage Measurement System) Max 0.2μm
Laser X-Y Movement Speed Max 45mm/s (without acceleration and deceleration)
Measurement Points Up to 19
  • Option : N2 FLOW MIXING METER
  • * The above specifications are subject to change without notice.